HV Coil winding machine for transformer
Usage:
Widely used in distributiontransformer, dry transformer,reactor and similar process of HV coil winding.
Composition:
It is main composed of winding host,wire guiding carriage with tensioner,insulation layer decoiler,
pneumatic system,PLC control ,operation touch screen and foot pedal.
Model
|
GRX-100
|
GRX-800
|
General
|
Dimension L×W×H
|
1400×2000×1300mm
|
2550×2180×1980mm
|
Winding width
|
500 mm
|
800mm
|
Weight
|
500kg
|
1000kg
|
Power supply
|
3×220(380)(415)V 50(60)HZ
|
3×220(380)(415)V 50(60)HZ
|
Coil
|
|
Coil diameter
|
80-400mm
|
80-600mm
|
Coil width (Max)
|
500mm
|
800mm
|
Coil weight(Max)
|
100kg
|
300kg
|
No.ofcoils wound simultaneously
|
1 or 2
|
1 or 2
|
Coil cross section
|
Round,oval,rectangle
|
Round,oval,rectangle
|
conductors
|
|
Round wire diameter
|
Φ0.3mm—Φ3mm
|
Φ0.3mm—Φ3mm
|
Flat wire
|
1×9mm
|
3×12mm
|
Mandrel
|
|
Speed adjustment method
|
Frequency stepless control
|
Frequency stepless control
|
Mandrel rotation speed (Max)
|
450rpm
|
450rpm
|
Mandrel torque
|
100Nm
|
100Nm
|